Serial Multiplexer - Collect Data From RS-232 Enabled Columns
       
Features

1
Can accept 4 serial port inputs from air columns, Weighing machine & any serial output instrument or device.
2
Membrane keypad.
3
Can capture data from air columns one by one or all the four readings in one keystroke.
4
Easily replaceable PS/2 connectors (One which is used for computer mouse) for keypad.
5
Baud rate selector.
6
Data collected will be stored in local or Network drive. Collected data can be centralized monitored.
7
KurtSPC / Serial Mux system sits on top of existing gages. KSPL offer complete solution including Industrial Panel PC & Gage table.

Various Input Protocols

1
Continuous
  
Data packets are sent continuously by the input device. A timeout condition will be generated if a packet is not received within a specified timeout duration. Protocols configured with the continuous communications method can only be used when communicating with serial devices.
2
Asynchronous
 
Data packets are sent by the device only when initiated by some action at the device. No timeout conditions will be generated for Asynchronous communication methods.
3
Asynchronous – Data
 
This method is similar to Asynchronous except that data will be automatically collected once the data packet has been received. This communications method is valid only when used inside of data collection.
4
Polled
 
Data packets are sent by the device only when polled by KurtSPC Software by sending a command to the device. This command can consist of a string of specific characters sent to the device or can be sent by toggling one of the hardware handshake lines of the serial port. Data for all data members will be sent by the device when polled. A timeout condition will be generated if no data is received within a specified time after it has been polled. Protocols configured with the polled communications method can only be used with serial devices or devices communicating over the network.
5
Polled by Member
 
Data packets are sent by the device only when polled by KurtSPC Software by sending a poll string to the device. Each data member will have a specified poll string; only the data for the member being polled will be sent by the device. A timeout condition will be generated if no data is received within a specified time after it has been polled. Protocols configured with the polled by member communication methods can only be used with serial devices or devices communicating over the network.


Data Storage

 KurtSPC Software is a Client/Server Application. So all SPC Data will be stored on Central Server. So if DataCollection PC fails,will you still have all SPC Data located on Central Server.


 